Fire extinguisher
Contents |
[edit] Introduction
Fire extinguishers are portable apparatus used to put out small fires in emergency situations. They work by distributing a suitable extinguishant (such as liquid, foam, powder and so on) onto the burning material to cut off its supply of oxygen or suppress the chemical reaction occurring in the flame.
[edit] History
The earliest forms of fire extinguisher were introduced in the Middle Ages. These devices, known as squirts, were pump-like devices with nozzles on the end.
The nozzle of the pump would be put into water, and a plunger would be used to pull the water into the squirt. The nozzle was then aimed at the fire, and the water stream would be directed towards the fire.
In 1723, Ambrose Godfrey was awarded the first official patent for a fire extinguisher. The German-born British chemist was best known for his production of phosphorus, but in 1724, he published a document entitled ‘New Method of Extinguishing Fires by Explosion and Suffocation’. His idea was to design a machine consisting of a cask of an aqueous solution surrounding a pewter chamber of gunpowder. The idea behind this was that a series of fuses would be detonated which would then make the gunpowder explode and distribute the liquid.
The first portable fire extinguisher was invented in 1819 by Captain George William Manby. His device consisted of a copper vessel containing a solution of potassium carbonate and compressed air.
Other early examples included:
- 1866 sodium bicarbonate and sulphuric acid with water
- 1904 chemical foam of sodium bicarbonate and aluminium sulphate.
- 1912 carbon tetrachloride (CTC).
- 1924 carbon dioxide.
![]() |
The 1924 carbon dioxide extinguisher invented by the Walter Kidde Company was made to put out fires in telephone switchboards. The device consisted of a metal cylinder with a wheel valve and a brass hose covered with cotton. The extinguisher in this photograph was made by the Walter Kidde Company for Bell Telephone in 1928. |
[edit] Fire extinguisher categories
In the UK, fire extinguishers are included in the standard BS EN 3 - Portable fire extinguishers. The extinguishers are colour coded to indicate which type of fires they should be used to extinguish:
- Water = Red
- Foam = Red with cream panel above the operating instructions
- Dry powder (generally a mix of monoammonium phosphate and ammonium sulfate, but not for combustible fires) = Red with blue panel above the operating instructions
- Carbon dioxide = Red with black panel above the operating instructions.
- Wet chemical (generally containing potassium acetate with potassium citrate or potassium bicarbonate) = Red with a bright yellow panel above the operating instructions.
- Class D powder (generally a mix of monoammonium phosphate and ammonium sulfate, but only for combustible fires) = Red with blue panel above the operating instructions.
[edit] Six fire classes
The UK recognises six fire classes:
- Class A fires involve organic solids such as paper and wood.
- Class B fires involve flammable or combustible liquids, including petrol, grease and oil.
- Class C fires involve flammable gases.
- Class D fires involve combustible metals.
- Class E fires involve electrical equipment/appliances.
- Class F fires involve cooking fat and oil.
Class A | Class B | Class C | Class D | Class E | Class F | |
Water | Yes | |||||
Foam | Yes | Yes | ||||
Dry powder | Yes | Yes | Yes | Yes | ||
Carbon dioxide | Yes | Yes | ||||
Wet chemical | Yes | Based on situation | Yes | |||
Class D powder | Yes |
While the powder inside fire extinguishers is non-toxic, contact should be limited. Precautions should be taken to minimise incidents where these circumstances could occur.
[edit] Maintenance
Fire extinguishers should be checked and maintained on a regular basis. While it’s uncommon for a device to have an expiration date, its reliability can degrade over time if it has not been properly maintained.
In the UK, there are three types of required maintenance:
- Basic. Annual service and inspection
- Extended. Five year test discharge and recharge.
- Overhaul: 10 year test for CO2 extinguishers.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Heat pumps, vehicle chargers and heating appliances must be sold with smart functionality.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
New-style degrees set for reformed ARB accreditation
Following the ARB Tomorrow's Architects competency outcomes for Architects.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.
Preserving, waterproofing and decorating buildings.
Many resources for visitors aswell as new features for members.
Using technology to empower communities
The Community data platform; capturing the DNA of a place and fostering participation, for better design.
Heat pump and wind turbine sound calculations for PDRs
MCS publish updated sound calculation standards for permitted development installations.
Homes England creates largest housing-led site in the North
Successful, 34 hectare land acquisition with the residential allocation now completed.
Scottish apprenticeship training proposals
General support although better accountability and transparency is sought.
The history of building regulations
A story of belated action in response to crisis.
Moisture, fire safety and emerging trends in living walls
How wet is your wall?
Current policy explained and newly published consultation by the UK and Welsh Governments.
British architecture 1919–39. Book review.
Conservation of listed prefabs in Moseley.
Energy industry calls for urgent reform.